Arc Rated Balaclava - Double Layer 34.0cal/cm2
A professional arc-rated balaclava designed to be worn under arc flash face shields, providing enhanced 360° head and neck protection. Rated to 34.0 cal/cm² (fabric rating), it protects vulnerable areas, including the neck and back of the head, during arc flash incidents.
The Reece Safety Arc Rated Balaclava (34 cal/cm²) is designed to provide additional arc flash protection where standard face shields alone may leave areas exposed.
Worn in combination with an arc-rated face protection shield, this balaclava helps protect the neck and back of the head — areas particularly vulnerable to thermal radiation during an arc flash event. It is an essential part of a layered arc-flash PPE system, providing improved coverage without adding unnecessary bulk.
For safety managers, it provides a straightforward way to enhance head protection as part of a documented arc flash risk control strategy. For engineers, it provides practical, close-fitting protection that integrates seamlessly with face shields and helmets.
As with all arc flash PPE supplied by Reece Safety, this balaclava is built to meet real-world electrical safety requirements.
Technical Specifications
-
Fabric Arc Rating: ASTM F1959 – ATPV 34.0 cal/cm²
-
System Arc Rating: ASTM F2178 – ATPV 26 cal/cm² (when worn with ELE9HINT shields)
-
Fabric Construction: Double layer fabric – 7.8 oz/yd²
-
Protection Coverage: 360° head and neck coverage
-
Application: For use under arc-rated face protection shields
-
Colour: Dark Blue
-
Size: Single size
Applications & Suitability
This arc-rated balaclava is intended for use in electrical environments where enhanced head and neck protection is required in combination with a face shield.
Typical applications include:
-
LV and HV switching activities
-
Panel access and diagnostics
-
Maintenance within established arc flash boundaries
-
Substation and industrial power distribution work
It is particularly suitable where arc flash risk assessments identify exposure to thermal radiation affecting the neck and the rear of the head.
Standards & Compliance
The fabric is arc flash tested according to:
-
ASTM F1959 – Fabric ATPV rating of 34.0 cal/cm²
-
ASTM F2178 – System ATPV rating of 26 cal/cm² when worn with ELE9HINT face shields
ATPV (Arc Thermal Performance Value) indicates the level of incident energy at which the onset of second-degree burn is predicted.
When used as part of a coordinated arc flash PPE system, this balaclava supports compliance with recognised electrical safety practices and employer duty-of-care obligations.
Protection Design & System Integration
The balaclava is designed specifically to be worn under Reece Safety’s range of arc-rated face shields.
Key protective benefits include:
-
360° coverage of the head and neck
-
Protection of the back of the head against arc thermal radiation
-
Close-fitting design to minimise gaps in PPE coverage
-
Double layer 7.8 oz/yd² fabric for enhanced thermal resistance
It should be integrated into a complete arc flash PPE system including arc-rated clothing, gloves and face protection appropriate to the calculated incident energy level.
Comfort & Practical Use
Designed for operational wear, this arc-rated balaclava offers:
-
Lightweight double-layer construction for balanced protection
-
Flexible fabric that fits comfortably beneath face shields
-
Single size design for straightforward issue across teams
-
Dark blue colour aligned with professional electrical PPE standards
This balance of protection and wearability helps ensure consistent use in live working environments.
Care, Inspection & Service Life
To maintain protective performance:
-
Inspect fabric for damage or contamination before each use
-
Do not use if exposed to arc flash or excessive wear
-
Clean according to manufacturer guidance only
-
Store in a clean, dry environment away from direct sunlight
Routine inspection supports compliance and ongoing PPE integrity.
Product Summary – Enhanced Head Protection for Arc Flash PPE Systems
The Reece Safety Arc Rated Balaclava (34 cal/cm² fabric rating) provides enhanced 360° head and neck protection when used with arc-rated face shields.
With independently tested arc ratings and practical integration into existing PPE systems, it offers a proportionate and defensible way to reduce exposure to thermal hazards during arc flash incidents.
Frequently Asked Questions
What does 34.0 cal/cm² refer to?
It is the fabric ATPV rating confirmed under ASTM F1959 testing.
What is the 26 cal/cm² rating?
This is the system ATPV rating achieved when the balaclava is worn together with ELE9HINT arc-rated face shields (ASTM F2178).
Can this balaclava be worn on its own?
No. It is designed to be worn in combination with an arc-rated face protection shield as part of a complete PPE system.
Why is neck protection important in arc flash incidents?
The neck and the rear of the head are vulnerable to thermal radiation during an arc flash. This balaclava provides coverage to reduce that exposure.